Castle VK037
Cena: 5 320.37€
Piegāde: pasūtāms
- Apraksts
The V9000 Seismograph is a portable battery operated ground vibration monitor, housed in an industrialised casing to withstand high intensity environments.
Primary industries monitoring ground vibration include:
Blasting
Piling
Demolition
Construction
Traffic
The V9000 also includes new features such as:Internet based remote capability
Frequency plotting in accordance with BS 5228 Part 2: 2009 and BS 7385 Part 2; 1993
Multiple text alarm functions
Larger screen with graphical representation
7 day timer function
Sleep mode
Basic and custom set up
Data storage for all 3 axes
Extended battery life of up to 40 days
Two Stage alarm - The two stage alarm comes with a standard 10 metre cable length, and battery charger. The alarm only uses power when it is activated, so the internal battery will last for between 3 – 4 months before requiring a re-charge. When activated, the alarm will operate for 15 seconds
before re-setting. The two stage alarm can work in conjunction with the text alarm function, on Seismographs which have the modem fitted.
Twin Channel Option - the twin channel transducer enables the V9000 to take measurements on a common time base in two locations simultaneously. It is also capable of measuring vibration dose values (VDV) to BS 6472 Part 1:2008
Vibrock V9000
Transducer
Primary industries monitoring ground vibration include:
Blasting
Piling
Demolition
Construction
Traffic
The V9000 also includes new features such as:Internet based remote capability
Frequency plotting in accordance with BS 5228 Part 2: 2009 and BS 7385 Part 2; 1993
Multiple text alarm functions
Larger screen with graphical representation
7 day timer function
Sleep mode
Basic and custom set up
Data storage for all 3 axes
Extended battery life of up to 40 days
Software
Once collected the results can be downloaded to a PC using the vibrock plug and play software. It can then be analysed after being exported to an excel spreadsheet.Two Stage alarm - The two stage alarm comes with a standard 10 metre cable length, and battery charger. The alarm only uses power when it is activated, so the internal battery will last for between 3 – 4 months before requiring a re-charge. When activated, the alarm will operate for 15 seconds
before re-setting. The two stage alarm can work in conjunction with the text alarm function, on Seismographs which have the modem fitted.
Optional Extras
Twin Channel Option - the twin channel transducer enables the V9000 to take measurements on a common time base in two locations simultaneously. It is also capable of measuring vibration dose values (VDV) to BS 6472 Part 1:2008
Number of Channels | 4 (optional 7) |
A/D Conversion | 1millisecond each channel |
A/D Resolution | 10 bit to 13mm/S then 10 bit to 200mm/S |
Resolution | 0.012mm/S to 13mm/S then 0.2mm/S |
Transducer | 3 component geophone pack |
Natural Frequency | 4Hz |
Length of Extension Cable | up to 1000metres |
Seismograph Power | 2 number D cells (Alkaline battery) |
Battery Life | 30 days continuous monitoring |
External Power | 12V DC |
Memory | Non-Volatile |
Memory Size | about 300 short trigger events or 30 days Continuous or any combination of these |
Communications Port | RS232 |
Communications Protocol | 8 bit no parity 9600 baud |
Measurement Parameters | Peak particle velocity (mm/S) Acceleration (g) Displacement (mm) Air Overpressure (dB) |
Instrument Protection | IP65 |
Transducer Protection | IP67 |
Conformity | CE |
Environmental | IEC 68-2 |
EMC Compliance | EN 61010, EN50 081, EN 50, 082 |
Weight of Instrument | 4Kg |
Transducer
Specifikācija